Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Filter by Categories
Case Report
Case Report, Comprehensive
Case Report, Cornea
Case Report, Glaucoma
Case Report, Neurophthalmology/Oncology
Case Report, Plastics
Case Report, Retina
Case Report, Uveitis
Case Series Retina
Case Series, Cornea
Case Series, Neurophthalmology/Oncology
Comprehensive, Editorial
Comprehensive, Original Article
Comprehensive, Review Article
Editorial
Glaucoma, Case Report
Glaucoma, Original Article
Glaucoma, Pictorial Essay
Media & News
Neuro-ophthalmology/Oncology, Original Article
Neuro-ophthalmology/Oncology, Review Article
Original Article
Original Article, Comprehensive
Original Article, Cornea
Original Article, Glaucoma
Original Article, Neurophthalmology/Oncology
Original Article, Retina
Pictorial Essay, Comprehensive
Pictorial Essay, Cornea
Pictorial Essay, Plastics
Pictorial Essay, Retina
Plastics, Case Report
Retina Pictorial Essay
Retina, Case Series
Retina, Original Article
Retina, Review Article
Review Article
Review Article, Retina
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Filter by Categories
Case Report
Case Report, Comprehensive
Case Report, Cornea
Case Report, Glaucoma
Case Report, Neurophthalmology/Oncology
Case Report, Plastics
Case Report, Retina
Case Report, Uveitis
Case Series Retina
Case Series, Cornea
Case Series, Neurophthalmology/Oncology
Comprehensive, Editorial
Comprehensive, Original Article
Comprehensive, Review Article
Editorial
Glaucoma, Case Report
Glaucoma, Original Article
Glaucoma, Pictorial Essay
Media & News
Neuro-ophthalmology/Oncology, Original Article
Neuro-ophthalmology/Oncology, Review Article
Original Article
Original Article, Comprehensive
Original Article, Cornea
Original Article, Glaucoma
Original Article, Neurophthalmology/Oncology
Original Article, Retina
Pictorial Essay, Comprehensive
Pictorial Essay, Cornea
Pictorial Essay, Plastics
Pictorial Essay, Retina
Plastics, Case Report
Retina Pictorial Essay
Retina, Case Series
Retina, Original Article
Retina, Review Article
Review Article
Review Article, Retina
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Filter by Categories
Case Report
Case Report, Comprehensive
Case Report, Cornea
Case Report, Glaucoma
Case Report, Neurophthalmology/Oncology
Case Report, Plastics
Case Report, Retina
Case Report, Uveitis
Case Series Retina
Case Series, Cornea
Case Series, Neurophthalmology/Oncology
Comprehensive, Editorial
Comprehensive, Original Article
Comprehensive, Review Article
Editorial
Glaucoma, Case Report
Glaucoma, Original Article
Glaucoma, Pictorial Essay
Media & News
Neuro-ophthalmology/Oncology, Original Article
Neuro-ophthalmology/Oncology, Review Article
Original Article
Original Article, Comprehensive
Original Article, Cornea
Original Article, Glaucoma
Original Article, Neurophthalmology/Oncology
Original Article, Retina
Pictorial Essay, Comprehensive
Pictorial Essay, Cornea
Pictorial Essay, Plastics
Pictorial Essay, Retina
Plastics, Case Report
Retina Pictorial Essay
Retina, Case Series
Retina, Original Article
Retina, Review Article
Review Article
Review Article, Retina
View/Download PDF

Translate this page into:

Original Article
Glaucoma
2026
:9;
1
doi:
10.25259/LAJO_41_2024

The impact of central corneal thickness on intraocular pressure measurement using Perkins applanation, iCare rebound, and Pulsair non-contact tonometers

Department of Ophthalmology, University of Port Harcourt Teaching Hospital, Port Harcourt, Nigeria.
Department of Ophthalmology, University of Port Harcourt, Port Harcourt, Nigeria.
Author image

*Corresponding author: Godswill Inye Nathaniel, Department of Ophthalmology, University of Port Harcourt, Port Harcourt, Nigeria. godswill.nathaniel@uniport.edu.ng

Licence
This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.

How to cite this article: Sibeudu OA, Nathaniel GI. The impact of central corneal thickness on intraocular pressure measurement using Perkins applanation, iCare rebound, and Pulsair non-contact tonometers. Lat Am J Ophthalmol. 2026;9:1. doi: 10.25259/LAJO_41_2024

Abstract

Objecives:

This study aims to compare the impact of central corneal thickness (CCT) on intraocular pressure (IOP) measurements using a non-contact tonometer (NCT), Pulsair, iCare rebound tonometer (RBT), and Perkins applanation tonometer (PAT) in adult patients at the Eye Clinic of University of Port Harcourt Teaching Hospital, Rivers State, Nigeria.

Material and Methods:

This was a comparative cross-sectional study of 92 (184 eyes) adults aged 18 and older. Their sociodemographic data were collected and an ocular examination was performed. Intraocular pressure measurements were done first using the NCT, then RBT, and finally PAT. An average of two readings was taken for all the devices, and there was a 10-minute interval between measurements. CCT was then assessed.

Results:

Using PAT, the mean pachymetrically corrected IOP by perkins applanation tonometer (cPAT) in the right eye (RE) was 15.48 ± 4.17 mmHg, and in the left eye (LE), cPAT was 14.16 ± 3.53 mmHg. Using NCT, pachymetrically corrected IOP with non-contact tonometer (cNCT) measured was 15.48 ± 3.55 mmHg (RE) and 15.55 ± 3.41 mmHg (LE). With RBT, pachymetrically corrected IOP using rebound tonometer (cRBT) was 16.54 ± 4.51 mmHg (RE) and 16.75 ± 4.09 mmHg (LE). There was a weak, statistically significant inverse correlation between pachymetrically corrected IOP and CCT for all instruments except with RBT in the RE. PAT was found to be the most affected by CCT following pachymetric correction, while RBT was the least affected.

Conclusion:

The PAT was most affected by the CCT, while the iCare RBT was least affected. It is necessary to have measured IOP corrected for CCT to get the true IOP.

Keywords

Central corneal thickness
Impact
Intraocular pressure
Measurement
Tonometers

INTRODUCTION

Central corneal thickness (CCT) has recently come to the limelight as an important factor in glaucoma diagnosis and progression. It is a measure of corneal rigidity and thus has an impact on the accuracy of intraocular pressure (IOP) measurement by tonometry. Opinions are varied on the significance in clinical practice of the effect of CCT on IOP measurements. Several researchers have found no direct correlation of IOP with CCT, while others have found a positive correlation of IOP with CCT.[1-3]

Several other studies have demonstrated that thicker corneas with greater rigidity offer more resistance when subjected to deformation, resulting in an artificially higher IOP reading.[4-7] Besides its effect on IOP measurement, it is an independent risk factor and a better predictor than IOP in identifying those at higher risk of developing primary open-angle glaucoma when combined with some ocular risk factors.[8] Several studies have shown the importance of corneal thickness on readings obtained with the Goldmann applanation tonometer (GAT).[5,9-11] Studies have also shown that about half of the ocular hypertension and normal tension glaucoma patients are misdiagnosed and probably inappropriately treated due to significantly abnormal corneal thickness.[12-14] A meta-analysis of over 600 data sets demonstrated that a 10% difference in CCT would result in a 3.4 ± 0.9 mm Hg difference in IOP (P ≤ 0.001, r = 0.419).[15]

Using a Pulsair non-contact tonometer (NCT) and GAT, Babalola et al. reported both instruments to be affected by variations in CCT, though the Pulsair (NCT) was more affected than GAT and tended to relatively overestimate IOP when CCT is high.[16] Similarly, Domke et al. found higher IOP values with NCT in thicker corneas when compared to GAT.[17] A better correspondence between both methods was observed in thinner corneas, suggesting that corneal rigidity increased with corneal thickness. This was unlike Rampersad et al., who found no relationship between CCT and IOP for any of the devices using the rebound tonometer (RBT), GAT, and Tonopachy.[18] and Iliev et al., who reported that both RBT and GAT were almost equally affected by CCT.[19]

Our practice, which initially depended more on the use of GAT and Perkins applanation tonometer (PAT), has recently seen the use of NCT and RBT. This study, therefore, aims to compare the impact of CCT on IOP measurement using PAT, Pulsair NCT, and iCare RBT.

MATERIAL AND METHODS

It was a comparative hospital-based cross-sectional study of adult participants 18 years and older carried out at the Eye Clinic of the University of Port Harcourt Teaching Hospital, Port Harcourt. Participants with severe visual impairment resulting in poor fixation, a history of intraocular surgery, refractive corneal surgery, and contact lens wear were excluded from the study. Also excluded were participants with corneal pathology such as keratoconus, bullous keratopathy, ocular inflammation, uncontrolled diabetes mellitus and hypertension, and corneal astigmatism exceeding 3 diopters.

A calculated sample size of 92 participants was used, and the participants were recruited into the study using systematic sampling techniques. Ethical clearance was obtained from the Ethical Committee of the University of Port Harcourt Teaching Hospital, Port Harcourt. Informed written consent was also obtained from all the participants. In addition, the study was conducted in compliance with the Helsinki tenets for research involving human subjects.[20]

Interviewer-administered questionnaires were used to collect the sociodemographic data from the participants. All participants then had a comprehensive ocular examination of both eyes.

IOP was measured for each eye first with the Keeler Pulsair NCT (Intellipuff USA NCT), then the iCare RBT (TA01i - Tiolat Oy. Helsinki, Finland), and finally the PAT (Mk 2 Haag-Streit Diagnostics). This was because the tonographic effect of the RBT and NCT due to aqueous massage is almost negligible and much less than PAT.[21] An interval of 10 minutes was given between measurements using each IOP instrument to improve the accuracy of sequential measurements.[22] All readings of IOP were taken between 8:00 am and 12:00 noon each day, to prevent the effect of diurnal variation, and readings were taken by different independent observers, each using a single device and masked from the values of the measurements of other devices. CCT was measured using an ultrasound pachymeter (Sonomed PacScan 300 AP+).

Data were analyzed using the Statistical Package for Social Sciences version 23. Results were presented in tables, bar charts, and scatter plots. Continuous variables were summarized with mean and standard deviation, while categorical variables were expressed with frequency and percentage. The relationship between the IOP measurements with the tonometers was assessed with Pearson correlation for significant correlation. A paired t-test was used to determine the mean difference between the IOP measurement levels of two instruments. Both NCT and RBT were validated with PAT. A linear regression model was used to determine the relationship between IOP and CCT between the instruments, in which the effect of the relationship, strength, and statistical significance (P-value) were determined. P < 0.05 was considered statistically significant in all cases (confidence level = 95%).

RESULTS

There were 69 (75%) and 23 (25%) male and female respondents in the study; most of whom were within the age group of 40–49 years, constituting 34 (37%) of the total respondents. The mean age was 38.84 ± 13.34 years, with an age range of 18–71 years. Few of the respondents had attained a tertiary degree, but the majority (n = 70; 76.1%) had a secondary level of education. There was a similar proportion of married and single respondents, about 48.9% (n = 45) and 45.7% (n = 42), respectively. The majority of the respondents were either semi-skilled, unemployed, or students [Table 1].

Table 1: Sociodemographic characteristics of the study participants.
Variables Frequency (n=92) Percentage
Sex
  Female 23 25.0
  Male 69 75.0
Age group (years)
  <30 26 28.3
  30–39 18 19.6
  40–49 34 37.0
  ≥50 14 15.2
Mean age (m±standard deviation) 38.84±13.34 years, age range 18–71 years
Education level
  No formal education 2 2.2
  Primary 16 17.4
  Secondary 70 76.1
  Tertiary 4 4.3
Marital status
  Single 42 45.7
  Married 45 48.9
  Widowed 3 3.3
  Separated/divorced 2 2.2
Occupation
  Professional 10 10.9
  Skilled 24 26.1
  Semi-skilled 29 31.5
  Student/unemployed 29 31.5

Characteristics of corrected IOP measurement by the various tonometers

The mean CCT corrected IOP using NCT in the right eye was 15.48 ± 3.55 mmHg and 15.55 ± 3.41 mmHg in the left eye. Using PAT, the mean CCT corrected IOP was 15.03 ± 4.17 mmHg in the right eye and 14.16 ± 3.53 mmHg in the left eye. For RBT, the mean CCT corrected IOP was 16.54 ± 4.51 mmHg in the right eye and 16.75 ± 4.09 mmHg in the left eye [Table 2].

Table 2: Descriptive characteristics of corrected IOP values from tonometers in the study.
Descriptives Corrected_Average_IOP
NCT PAT RBT
Right eye
  Mean 15.48 15.03 16.54
  Median 15.25 14.30 16.30
  Standard deviation 3.55 4.17 4.51
  Interquartile range 3.40 4.35 4.92
  Minimum 9.80 7.10 9.40
  Maximum 36.00 39.00 41.50
Left eye
  Mean 15.55 14.16 16.75
  Median 15.20 13.55 16.20
  Standard deviation 3.41 3.53 4.09
  Interquartile range 4.85 4.63 6.03
  Minimum 9.90 7.00 9.10
  Maxi mum 28.40 28.10 32.10

IOP: Intraocular pressure, NCT: Non-contact tonometer, PAT: Perkins applanation tonometer, RBT: Rebound tonometer

Comparison of PAT, NCT, and RBT IOP measurements

RBT indicated elevated IOP in the greatest number of eyes, 8 right eyes and 12 left eyes, while PAT and NCT measured elevated IOP in the least number of eyes. PAT measured elevated IOP in 4 right eyes, whereas NCT did in 3, and on the left, PAT measured elevated IOP in 3 eyes, while NCT did in 4 eyes [Figure 1].

Intraocular pressure classification of non-contact Pulsair, Perkins, and rebound tonometer. RE: Right eye, LE: Left eye, PAT: Perkins applanation tonometer, RBT: Rebound tonometer, NCT: Noncontact tonometer.
Figure 1:
Intraocular pressure classification of non-contact Pulsair, Perkins, and rebound tonometer. RE: Right eye, LE: Left eye, PAT: Perkins applanation tonometer, RBT: Rebound tonometer, NCT: Noncontact tonometer.

Correlation between corrected IOP and CCT

There was a statistically significant weak positive correlation between corrected IOP and CCT of all three instruments in both eyes, except for cRBT and CCT on the right eye, P = 0.05 [Table 3].

Table 3: Correlation between corrected intraocular pressure and central corneal thickness.
Variables Correlation coefficient P-value
Right eye
  cPAT and Central corneal thickness −0.394 0.000*
  cNCT and central corneal thickness −0.383 0.000*
  cRBT and central corneal thickness −0.205 0.050
Left eye
  cPAT and central corneal thickness −0.464 0.000*
  cNCT and central corneal thickness −0.392 0.000*
  cRBT and central corneal thickness −0.223 0.032*
means that p-value is statistically significant because p-value<0.005, cPAT: Pachymerically correced IOP with Perkins Applanation tonometer, cNCT: Pachymetrically corrected IOP with Non-Contact tonometer, cRBT: Pachymetrically corrected IOP with iCare Rebound tonometer.

Correlation plots between corrected IOP and CCT using PAT, NCT, and RBT

There was a weak (−0.394) but statistically significant (<0.001) negative correlation between corrected IOP_PAT and CCT of the right eye. However, CCT accounted for a change in IOP in only 15.5% of the time. There was a weak (0.464) but statistically significant (<0.001) negative correlation between corrected IOP_PAT and CCT of the left eye. However, CCT accounted for a change in IOP in only 21.6% of the time [Figure 2].

Correlation plot (a and b) between cPAT and central corneal thickness in the right and left eyes. cPAT: Pachymetrically corrected IOP with Perkins applanation tonometer, CCT: Central corneal thickness, RE: Right eye, LE: Left eye, PAT: Perkins applanation tonometer.
Figure 2:
Correlation plot (a and b) between cPAT and central corneal thickness in the right and left eyes. cPAT: Pachymetrically corrected IOP with Perkins applanation tonometer, CCT: Central corneal thickness, RE: Right eye, LE: Left eye, PAT: Perkins applanation tonometer.

Similarly, there is a weak (−0.383) but statistically significant (<0.001) negative correlation between corrected IOP_NCT and CCT of the right eye. The CCT accounted for a change in IOP in only 14.7% of the time. There was a weak (−0.392) but statistically significant (<0.001) negative correlation between corrected IOP_NCT and CCT of the left eye, and the CCT accounted for the change in IOP only 15.3% of the time [Figure 3].

Correlation plot (a and b) between cNCT and central corneal thickness in the right and left eyes. cNCT: pachymetrically corrected IOP measured with non-contact tonometer, IOP: Intraocular pressure, NCT: Non-contact tonometer, RE: Right eye, LE: Left eye, CCT: Central corneal thickness
Figure 3:
Correlation plot (a and b) between cNCT and central corneal thickness in the right and left eyes. cNCT: pachymetrically corrected IOP measured with non-contact tonometer, IOP: Intraocular pressure, NCT: Non-contact tonometer, RE: Right eye, LE: Left eye, CCT: Central corneal thickness

There was a weak (−0.205) statistically insignificant (0.050) negative correlation between corrected IOP_RBT and CCT of the right eye, and the CCT accounted for the change in IOP only 4.2% of the time. There was also a weak (−0.223) but statistically significant (<0.032) negative correlation between corrected IOP_RBT and CCT of the left eye. The CCT accounted for a change in IOP in only 5.0% of the time [Figure 4].

Correlation plot (a and b) between cRBT and central corneal thickness in the right and left eyes. cRBT: Pachymetrically corrected intraocular pressure with Rebound tonometer, RE: Right eye, LE: Left eye, CCT: Central corneal thickness.
Figure 4:
Correlation plot (a and b) between cRBT and central corneal thickness in the right and left eyes. cRBT: Pachymetrically corrected intraocular pressure with Rebound tonometer, RE: Right eye, LE: Left eye, CCT: Central corneal thickness.

DISCUSSION

There have been conflicting reports on the correlation between IOP and CCT. Several studies have shown a positive correlation between IOP and CCT.[2,6,11,23-25] On the other hand, several others have shown no correlation between IOP and CCT.[12,18,26,27] In this study, following pachymetric correction, there was a weak statistically significant inverse correlation between IOP and CCT using all three instruments except with RBT in the right eye (P > 0.05). Thus, as CCT was increasing, there was a corresponding decrease in pachymetrically corrected IOP. This mirrors the findings of other researchers such as Adegbehingbe et al., Gustavo et al., Rampersad et al., and Brandt et al., but is at variance with others such as Kohlhaas et al., Wolfs et al., and Farrahi et al.[12,18,23,26,28,29,30] Martinez-De-La-Casa et al. and Gustavo et al. compared all three and found a weak but significant correlation of IOP measurements using NCT, RBT, and GAT with CCT, resulting in overestimation of the IOP in subjects with thick corneas and underestimation in those with thin corneas.[29 ,31]

From the regression analysis for corrected IOP and CCT in both eyes, PAT was the most affected by CCT, and RBT was the least affected by CCT, as illustrated by the lower r values. This varies with the findings of Tonnu et al.[32] and Babalola et al.[16] who reported that GAT was less affected by CCT than NCT.[16,33] Also, Iliev et al. reported both RBT and GAT to be almost equally affected by CCT.[19] These discrepancies could have been because Tonnu’s study used only glaucoma patients and suspects, or because Iliev’s study had a much smaller sample size (about half that of this study), or because PAT rather than GAT was used in this study, in contrast to all three studies.

Thus, to sum up, similar to other studies, with increasing CCT, there was a corresponding decrease in corrected IOP, and CPAT was the most affected by CCT of all three tonometers.[2,6,11,23-25,31] The weak correlation between CCT and IOP with all the instruments suggests that other factors other than CCT are responsible for changes in IOP measurements. These factors include central corneal curvature, corneal hysteresis, and corneal resistance factor.[29,33,34]

Essentially, RBT and NCT show an overestimation of IOP measurements relative to GAT/PAT, tonometer preference is varied, could even be said to be equivocal, but the majority of studies show a proclivity for instruments with minimal patient contact such as RBT and NCT. There are conflicting reports on the association of CCT and IOP.

CONCLUSION

The PAT was most affected by the CCT, while the iCare RBT was least affected. It is necessary to have measured IOP corrected for CCT to get the true IOP.

Ethical approval:

The research was approved by the Ethics Committee of the University of Port Harcourt Teaching Hospital, Port Harcourt with the approval number UPTH/ADM/90/S.II/VOL.XI/616 dated 12th June 2018.

Declaration of patient consent:

The authors certify that they have obtained all appropriate patient consent forms. In the form, the patients have given their consent for their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Conflicts of interest:

There are no conflicts of interest.

Use of artificial intelligence (AI)-assisted technology for manuscript preparation:

The authors confirm that there was no use of artificial intelligence (AI)-assisted technology for assisting in the writing or editing of the manuscript and no images were manipulated using AI.

Financial support and sponsorship: Nil.

References

  1. , , . Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings. Br J Ophthalmol. 2001;85:85-7.
    [CrossRef] [PubMed] [Google Scholar]
  2. , , , , . Corneal thickness and intraocular pressure in the Barbados eye studies. Arch Ophthalmol. 2003;121:240-4.
    [CrossRef] [PubMed] [Google Scholar]
  3. , , , , , . Central corneal thickness and intraocular pressure of adult Nigerians: An assessment of Zaria community. Niger J Ophthalmol. 2015;23:1-2.
    [Google Scholar]
  4. . Applanation tonometry and correction according to corneal thickness. Acta Ophthalmol Scand. 1998;76:319-24.
    [CrossRef] [PubMed] [Google Scholar]
  5. , , . The effect of corneal thickness on applanation tonometry. Am J Ophthalmol. 1993;115:592-6.
    [CrossRef] [PubMed] [Google Scholar]
  6. , , , , , . Central corneal thickness and intraocular pressure in a Mongolian population. Ophthalmology. 1998;105:969-73.
    [CrossRef] [PubMed] [Google Scholar]
  7. , , , , . Central corneal thickness in Latinos. Invest Ophthalmol Vis Sci. 2003;44:1508-12.
    [CrossRef] [PubMed] [Google Scholar]
  8. , . The relationship between central corneal thickness and intraocular pressure: A comparative study of normals and glaucoma subjects. Afr J Med Med Sci. 2008;37:345-53.
    [Google Scholar]
  9. , , . Applanation tonometry and central corneal thickness. Acta Ophthalmol (Copenh). 1975;53:34-43.
    [CrossRef] [PubMed] [Google Scholar]
  10. , . Elevated tonometer readings caused by a thick cornea. Acta Ophthalmol (Copenh). 1971;49:775-8.
    [CrossRef] [PubMed] [Google Scholar]
  11. . A clinical study of the normal human central corneal thickness. Acta Ophthalmol. 1971;49:82-9.
    [CrossRef] [PubMed] [Google Scholar]
  12. , , , . Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS) Ophthalmology. 2001;108:1779-88.
    [CrossRef] [PubMed] [Google Scholar]
  13. , , . Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma. Arch Ophthalmol. 1999;117:14-6.
    [CrossRef] [PubMed] [Google Scholar]
  14. . Ocular hypertension and central corneal thickness. Ophthalmology. 1995;102:1810-2.
    [CrossRef] [PubMed] [Google Scholar]
  15. , . Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach. Surv Ophthalmol. 2000;44:367-408.
    [CrossRef] [PubMed] [Google Scholar]
  16. , , , , , . A comparison of the Goldmann applanation and non-contact (Keeler Pulsair EasyEye) tonometers and the effect of central corneal thickness in indigenous African eyes. . 2009;29:182-8.
    [CrossRef] [PubMed] [Google Scholar]
  17. , , . Intraocular pressure and corneal thickness. A comparison between non-contact tonometry and applanation tonometry. Der Ophthalmol. 2006;103:583-7.
    [Google Scholar]
  18. , , . A comparison of intraocular pressure values obtained with the Tono-Pachymeter NT530P, iCare® rebound tonometer and Goldmann applanation tonometer. Afr Vision Eye Health. 2015;74:10.
    [Google Scholar]
  19. , , , , . Comparison of rebound tonometry with Goldmann applanation tonometry and correlation with central corneal thickness. Br J Ophthalmol. 2006;90:833-5.
    [CrossRef] [PubMed] [Google Scholar]
  20. . World Medical Association Declaration of Helsinki: Ethical principles for medical research involving human subjects. JAMA. 2013;310:2191-4.
    [CrossRef] [PubMed] [Google Scholar]
  21. , , , , . Evaluierung der reboundtonometrie (ICare) im vergleich zum TonoPenXL und dem goldmannapplanations tonometer originalien einleitung. Ophthalmologe. 2007;104:299-304.
    [CrossRef] [PubMed] [Google Scholar]
  22. , , , . Comparability of Icare pro rebound tonometer with goldmann applanation and noncontact tonometer in a wide range of intraocular pressure and central corneal thickness. Ophthalmic Res. 2015;54:18-25.
    [CrossRef] [PubMed] [Google Scholar]
  23. , , , , , . Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study. Am J Ophthalmol. 1997;123:767-72.
    [CrossRef] [PubMed] [Google Scholar]
  24. , , , , , , et al. Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik Eye Study. Acta Ophthalmol Scand. 2002;80:11-5.
    [CrossRef] [PubMed] [Google Scholar]
  25. , . Factors affecting the central corneal thickness of Hong Kong-Chinese. Curr Eye Res. 1999;18:368-74.
    [CrossRef] [PubMed] [Google Scholar]
  26. , , , , , . Central cornea thickness in glaucoma and non-glaucoma African population. Ophthalmol Res An Int J. 2016;6:1-8.
    [CrossRef] [PubMed] [Google Scholar]
  27. , , , , . Relationship between intraocular pressure and central corneal thickness in adults in port hacourt city local government area. Niger J Ophthalmol. 2016;23:9.
    [Google Scholar]
  28. , , , , , . Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry. Arch Ophthalmol. 2006;124:471-6.
    [CrossRef] [PubMed] [Google Scholar]
  29. , , , , . Modalities of tonometry and their accuracy with respect to corneal thickness and irregularities. J Optom. 2008;1:43-9.
    [CrossRef] [Google Scholar]
  30. , , , . Comparison of IOPen rebound tonometer with Goldmann applanation tonometer at different IOP levels. Int J Ophthalmol. 2013;6:637-40.
    [Google Scholar]
  31. , , , , , , et al. Performance of the rebound, noncontact and Goldmann applanation tonometers in routine clinical practice. Acta Ophthalmol. 2011;89:676-80.
    [CrossRef] [PubMed] [Google Scholar]
  32. , , , , , , et al. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol. 2005;89:851-4.
    [CrossRef] [PubMed] [Google Scholar]
  33. , , , . Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics, and African Americans. Am J Ophthalmol. 2003;136:603-13.
    [CrossRef] [PubMed] [Google Scholar]
  34. , , , . Comparison of current tonometry techniques in measurement of intraocular pressure. J Curr Ophthalmol. 2017;29:92-7.
    [CrossRef] [PubMed] [Google Scholar]
Show Sections